Ilumipod Inground Tri-3 IP Optic 25 RGB QRG 10 DMX Values ARC 1 Channel Function Value Percent/Setting 1 Red 000 ó 255 0 ~ 100% 2 Green 000 ó 255
Ilumipod Inground Tri-3 IP Optic 25 RGB QRG 11 ARC FULL Channel Function Value Percent/Setting 1 Dimmer 000 ó 255 0 ~ 100% 2 Red 000 ó 255 0 ~ 10
Ilumipod Inground Tri-3 IP Optic 25 RGB QRG 12 Contact Us World Headquarters ILUMINARC® General Information Address:
Ilumipod Inground Tri-3 IP Optic 25 RGB QRG 2 About This Guide The Ilumipod Inground Tri-3 IP Optic 25 RGB Quick Reference Guide (QRG) only contains
Ilumipod Inground Tri-3 IP Optic 25 RGB QRG 3 Features • 1, 3, 4, or 7-channel DMX-512 LED inground washlight • Operating modes: 1-channel: Dimme
Ilumipod Inground Tri-3 IP Optic 25 RGB QRG 4 AC Power This product has an auto-ranging power supply that works with an input voltage range of 100~2
Ilumipod Inground Tri-3 IP Optic 25 RGB QRG 5 DMX Connection You can connect the bare-ended IP67 rated signal cable from this product to two IP67 ra
Ilumipod Inground Tri-3 IP Optic 25 RGB QRG 6 Ilumicon and DMX Controllers The Ilumipod Inground Tri-3 IP Optic 25 RGB can operate with either an Il
Ilumipod Inground Tri-3 IP Optic 25 RGB QRG 7 Installation Before installing this product, read the Safety Notes at the beginning of the Ilumipod
Ilumipod Inground Tri-3 IP Optic 25 RGB QRG 8 Ilumicode Control Panel Description Button Function <POWER> Turns the Ilumicode Addresser on
Ilumipod Inground Tri-3 IP Optic 25 RGB QRG 9 Menu Options Main Level Programming Levels Description DMX 001~512 N/A Sets the DMX starting address P